Benefits


  • Reduced light overspill and glare with excellent forward throw of light
  • Multiple options for effective light distribution as the adjustable lamp holder offers three variations of peak beam elevation
  • Dark skies friendly fitting. Ideal for projects near to residential areas with specific light regulations
  • Ease of maintenance via two rear doors with no requirement for tools
Challenger ® 1 - AL6000

Challenger®1

AL6000




IP66Upward Light Output Ratio 0% at 60°Light Control System
Download PDF

Abacus Light Control System
Efficient, careful lighting design has given Abacus an international reputation for combining powerful, sharp illumination with low light pollution. Abacus’ Lighting Control System - exclusive to the Challenger® 1 - features a series of complementary technologies to help achieve this.

The Abacus Light Control System

Double Asymmetric Reflector
The double asymmetric reflector is designed to better concentrate and focus the light produced by each lantern. By emitting the main beam at an angle of 55, 60 or 65 degrees from the normal to the front glass, it results in a flat appearance, making less of the reflector visible to spectators as well minimising glare.

Double Asymmetric Reflector


On this page: Dimensions | Photometry | Lamp options

Technical Features
  • High powered lamp capabilities 1kW / 2kW metal halide
  • 1000W and 2000W MHN-LA & MHN-FC 2200W, MH-TS2000W/XL, HQI-TS2000WNL
  • High pressure die cast aluminium type EN AC 43400
  • Stainless steel clamps and fixings
  • 6mm galvanised steel mounting bracket with M20 bolt hole
  • 4mm tempered, low iron, high transmission glass
  • IP66, IK08 ratings, CE marked
  • Available in double asymmetric: narrow, medium and wide beam distributions
  • High purity, polished and anodised aluminium reflector system
  • 60° peak beam elevation as standard on all beam widths
  • Lamp holder support can be adjusted for 55° and 65° peak beam elevation capabilities as standard
  • Upward Light Output Ratio (ULOR): <0% at 60° peak beam elevation
  • Low light pollution resulting in a dark skies friendly lantern
  • Front, rear and side cowl available
  • Electrical connection box : (IP66) housing containing the ignitor and the power connection, located on the side of the stirrup
  • Fitted with 2 x GORE™ membrane breathers for floodlight air pressure regulation
  • Toolless lamp access via two rear doors, secured with hand operated latches

Maintenance
Easy Maintenance: Access to the lamp by means of opening the rear door Easy Maintenance: Access to the lamp by means of opening the rear door

Challenger® 1 - AL6000

Dimensions
Challenger ® 1 - DimensionsMounting: Stirrup mounted using M20 fixing
Stirrup adjustment +/- 140°

Challenger ® 1 - Dimensions Weight: 21.4kg.
Front wind area: @60° setting (Flat Glass) - 0.126m² 70° max setting (+10 elevation) - 0.135m².
Side wind area: 0.108m²

All dimensions are in mm.

Photometry

Narrow 55° Challenger 1 Narrow beam 55 deg


Medium 55° Challenger 1 Medium beam 55 deg


Wide 55° Challenger 1 Wide beam 55 deg


Narrow 60° Challenger 1 Narrow beam 60 deg


Medium 60° Challenger 1 Medium beam 60 deg


Wide 60° Challenger 1 Wide beam 60 deg


Narrow 65° Challenger 1 Narrow beam 65 deg


Medium 65° Challenger 1 Medium beam 65 deg


Wide 65° Challenger 1 Wide beam 65 deg



  Wattage (kW) Beam Type Lamp Lamp Manufacturer Lamp Reference Weight (kg)
AL6001 2.2 Narrow MHN-FC/B Philips MHN-FC2.2KW400V/640 21.4
AL6002 2.2 Medium MHN-FC/B Philips MHN-FC2.2KW400V/640 21.4
AL6003 2.2 Wide MHN-FC/B Philips MHN-FC2.2KW400V/640 21.4
AL6004 2 Narrow MHN-LA Philips MHN-LA2KW400V/842 21.4
AL6005 2 Medium MHN-LA Philips MHN-LA2KW400V/842 21.4
AL6006 2 Wide MHN-LA Philips MHN-LA2KW400V/842 21.4
AL6007 2 Narrow HQI-TS/N/L Osram HQI-TS2000WNL 21.4
AL6008 2 Medium HQI-TS/N/L Osram HQI-TS2000WNL 21.4
AL6009 2 Wide HQI-TS/N/L Osram HQI-TS2000WNL 21.4
AL6010 1 Narrow MHN-FC Philips MHN-FC1KW230V/740 21.4
AL6011 1 Medium MHN-FC Philips MHN-FC1KW230V/740 21.4
AL6012 1 Wide MHN-FC Philips MHN-FC1KW230V/740 21.4
AL6013 2 Narrow MH-TS 2kW/XL Venture MH-TS2000W/XL/K12/745 21.4
AL6014 2 Medium MH-TS 2kW/XL Venture MH-TS2000W/XL/K12/745 21.4
AL6015 2 Wide MH-TS 2kW/XL Venture MH-TS2000W/XL/K12/745 21.4
AL6016 1 Narrow MHN-LA 842 Philips MHN-LA1KW230V/842 21.4
AL6017 1 Medium MHN-LA 842 Philips MHN-LA1KW230V/842 21.4
AL6018 1 Wide MHN-LA 842 Philips MHN-LA1KW230V/842 21.4
AL6019 1 Narrow MHN-LA 956 Philips MHN-LA1KW230V/956 21.4
AL6020 1 Medium MHN-LA 956 Philips MHN-LA1KW230V/956 21.4
AL6021 1 Wide MHN-LA 956 Philips MHN-LA1KW230V/956 21.4
AL6022 2 Narrow MHN-LA 956 Philips MHN-LA2KW400V/956 21.4
AL6023 2 Medium MHN-LA 956 Philips MHN-LA2KW400V/956 21.4
AL6024 2 Wide MHN-LA 956 Philips MHN-LA2KW400V/956 21.4

Lamp references

HQI-TS

MHN-LA
MHN-FC

Lamp Manufacturer
& Lamp Ref.
Wattage (kW) Colour Temp (K) RA Lamp Lumen Output:
(Initial lm)
Lamp Current (A) Supply Voltage (V) Total Circuit Power (W)
Venture              
MH-TS2000W/XL/K12/745 2 4500 65 240,000 10.3 380/400/415 2150
Philips              
MHN-FC2.2KW400V/640 2.2 4100 60 232,000 11 380/400/415 2150
MHN-LA2KW400V/842 2 4100 80 220,000 9.6 380/400/415 2105
MHN-LA2KW400V/956 2 5600 90 190,000 10.3 380/400/415 2113
MHN-LA1KW230V/842 1 4200 70 95,800 9.3 230/240 1040
MHN-LA1KW230V/956 1 5600 80 87,000 9.3 230/240 1040
MHN-FC2KW400V/740 2 4200 60 210,000 10.11 380/400/415 2105
MHN-FC1KW230V/740 1 4100 65 93,000 8.9 230/240 1040
Osram              
HQI-TS2000WNL 2 4100 65 230,000 10.4 380/400/415 2105

Technical information may alter dependent on control gear used